Series 8000 AM - Alloy Muffle Dual Chamber Furnaces

Unique “Space Saver” design offers the convenience and economy of two independently controlled chambers in one packaged assembly. The upper chamber (Hardening) is equipped with an alloy muffle for operation with a positive flow of atmosphere to 2050°F. The alloy muffle separates the chamber refractory and heating elements from the workload and atmosphere to minimize scale and oxidation on most tool steels. This design achieves lower dew points in the work chamber, reduces atmosphere consumption and shortens purge time. The AM models are ideal for cyclical or production type applications.

The lower chamber (Tempering) is complete with a stainless steel liner and fan to recirculate the heat for uniform temperature. Available at operating temperatures of 800°F(88), 1200°F(82), 1400°F(84), and 1600°F(86). Ideal for Tool Rooms and Schools, providing a complete heat treat station in one furnace.

Ruggedly constructed and rated for work loads up to 50 lbs. per square foot of hearth area. All models are completely wired, assembled, test fired and shipped ready for connection to main power supply. Compact design, fast installation, and simple, safe, dependable operation. All models will operate with inert atmosphere. Flammable atmosphere may be used with the addition of Atmosphere Safety System per NFPA Code 86 C.

Standard Features

  • Welded sheet metal single shell construction.
  • Both chambers designed with same working dimensions.
  • Heavy gauge coil wound low watt density heating elements for longer life.
  • High grade alloy muffle with inlet pipe and front flange.
  • Multi-layered energy efficient lightweight firebrick and mineral block insulation for maximum heat storage and minimum heat loss.
  • Elements mounted in easy-to-replace holders located on side walls and below the hearth for uniform temperature on upper chamber.
  • Silicon carbide hearth plate for muffle support and thermal transfer from floor elements in upper chamber.
  • Manual vertical lift door (8000 AM) and double pivot horizontal swing doors (85AM & 89AM) with high temperature ceramic fiber gasket on upper chamber.
  • Safety micro-switch shuts off power to elements and fan on lower chamber when door opens.
  • Honeywell digital temperature controller with type K thermocouple and magnetic contactor on each chamber.
  • Controls are mounted in a side mounted NEMA 1 panel and operate on 115 volts.

Recent news

Options

Flow meters, regulators, oxygen analyzers, dew point indicators, muffle thermocouples, cascade and multi-zone control systems, supervised flame curtains, supervised burn-off systems, program controllers, over temperature safety systems, cooling systems, timers, recorders, quench tanks, alternate door arrangements, computer interface, special voltages, gloves and tongs.

 

8000 AM

Model Chamber Overall KW Voltage Weight (lbs)
H" W" L" H" W" L"
82AM-C12 5 5 12 80 32 42 6 230/1 725
82AM-C18 5 5 18 80 32 48 7.5 230/1 800
82AM-F12 7 7 12 84 35 42 9 230/1 875
82AM-F18 7 7 18 84 35 48 11.5 230/1 1000
82AM-I12 10 10 12 92 38 42 11.5 230/1 1150
82AM-I18 10 10 18 92 38 48 14.5 230/3 1285
82AM-I24 10 10 24 92 38 54 19.5 230/3 1400
82AM-I36 10 10 36 92 38 68 25 230/3 2050

8500 AM

Model Chamber Overall KW Voltage Weight (lbs)
H" W" L" H" W" L"
85AM-G18 8 12 18 68 40 48 14.5 230/460/3 1425
85AM-G24 8 12 24 68 40 54 19 230/460/3 1550
85AM-G36 8 12 36 68 40 66 24.5 230/460/3 1700
85AM-J18 10 15 18 70 43 48 21.5 230/460/3 2500
85AM-J24 10 15 24 70 43 54 25 230/460/3 2800
85AM-J36 10 15 36 70 43 66 30 230/460/3 3350
85AM-K12 12 12 12 72 40 42 14.5 230/460/3 1600
85AM-K18 12 12 18 72 40 48 20 230/460/3 2400
85AM-K24 12 12 24 72 40 54 24.5 230/460/3 2800
85AM-K36 12 12 36 72 40 66 29 230/460/3 3400

8900 AM

Model Chamber Overall KW Voltage Weight (lbs)
H" W" L" H" W" L"
89AM-M24 12 18 24 72 46 54 29 230/460/3 2950
89AM-M36 12 18 36 72 46 66 39 230/460/3 3300
89AM-N24 15 15 24 76 43 54 30 230/460/3 3100
89AM-N30 15 15 30 76 43 60 36 230/460/3 3250
89AM-N36 15 15 36 76 43 66 42 230/460/3 3500
89AM-O18 18 18 18 80 46 48 32 230/460/3 3100
89AM-O24 18 18 24 80 46 54 39 230/460/3 3400
89AM-O36 18 18 36 80 46 66 46 230/460/3 3900