Series 7000 EQ - Elevator Quench Controlled Atmosphere Furnaces

Elevator Quench Furnaces combine a pre-heat section, hardening chamber, cooling vestibule and quench tank in one complete unit with operation to 2050°F. The workload is processed in the furnace chamber then pulled into the vestibule area where the parts can be automatically lowered by an air-operated elevator into a quench tank without exposing the parts to air. The furnaces are complete with an alloy muffle which separates the atmosphere and workload from the refractory and elements, and an inner door which separates the furnace chamber from the vestibule section. An outer door provides a positive seal against the vestibule. The EQ Models operate under a positive flow of protective atmosphere to minimize scale and oxidation on most tool steels. This design achieves lower dew points, reduces atmosphere consumption and shortens purge time.

Ruggedly constructed, compact design, easy installation, and simple, safe, dependable operation. All models are completely wired, test fired and shipped ready for connection to main power and regulated atmosphere pressure of 5 PSI. All models will operate with inert atmosphere. Flammable atmosphere may be used with the addition of Atmosphere Safety System per NFPA Code 86 C.

Standard Features

  • Welded sheet metal shell construction with structural reinforcement.
  • Heavy gauge coil wound low watt density heating elements for longer life.
  • High grade alloy muffle with inlet pipe and front flange.
  • Manual vertical lift inner and outer door assemblies.
  • Air operated elevator quench basket.
  • Quench tank constructed from continuously welded mild steel.
  • Multi-layered energy efficient lightweight firebrick and mineral block insulation for maximum heat storage and minimum heat loss.
  • Elements mounted in easy-to-replace holders located on side walls and below the hearth for uniform temperature.
  • Silicon carbide hearth plate for full muffle support and thermal transfer from floor elements.
  • Honeywell digital temperature controller with type K thermocouple and contactor.
  • Controls are mounted in separate side mounted NEMA 1 panel and operate on 115 volts.

Specifications

Model Chamber Overall KW Voltage Weight (lbs) Max Work Load (lb) Quench Tank (gal)
H" W" L" H" W" L"
7EQ-C12 5 5 12 68 31 68 4 230/1 975 15 20
7EQ-C18 5 5 18 68 31 73 5.5 230/1 1100 20 25
7EQ-F12 7 7 12 70 33 68 6.5 230/1 1050 25 30
7EQ-F18 7 7 18 70 33 73 8 230/460/1 1175 30 35
7EQ-I12 10 10 12 73 36 68 8 230/460/1 1200 30 35
7EQ-I18 10 10 18 73 36 73 10 230/460/1 1325 35 45
7EQ-I24 10 10 24 73 36 86 13 230/460/3 1500 45 55
7EQ-I36 10 10 36 73 36 112 16 230/460/3 1700 55 70